Lutron Electronic Dimming Ballast for T5 Twin-Tube Lamps

Models EcoSystem & Eco-10

1-800-843-6036

Email us

OnLine Order

Supported Browsers:  IE, SAFARI, CHROME

MORE LUTRON PRODUCTS

Lutron dimming ballast ballasts EcoSystem Ballasts connect directly to all EcoSystem sensors and wallstations. Direct connections eliminate interfaces, powerpacks, and long conduit runs, supporting EcoSystem "plug and play" capabilities

Lutron EcoSystem Ballasts connect directly to all EcoSystem sensors and wallstations. Direct connections eliminate interfaces, powerpacks, and long conduit runs, supporting EcoSystem "plug and play" capabilities
  • Features: Lutron EcoSystem Ballasts
  • Continuous, flicker-free dimming from 100% to 10%
  • Provides power for and responds to sensors and controls
  • Communicates status and sensor inputs over the EcoSystem Bus
  • Programmed rapid start design ensures full rated lamp life
  • Lamps turn on to any dimmed level without flashing to full brightness
  • Low harmonic distortion throughout the entire dimming range
  • Operating frequency ensures ballast does not interfere with IR devices
  • End-of-lamp-life protection circuitry ensures safe operation
  • Ultra-quiet operation
  • Nonvolatile memory restores all ballast settings after power failure
  • Ballasts maintain consistent light output for differing lamp lengths
  • 100% performance tested at factory
  • T5 Twin-Tube Dimming Ballasts EcoSystem & Eco-10   

    Lamp Wattage Lamps per Ballast Model Number WEB PRICE EACH Case Type Dimming Level Control Type
    Voltage (V) Current (A) Input Power (W) Ballast Factor System Lumens (*) Efficacy (lm/W) (*) BEF RSE Power Factor THD
    36W EcoSystem
    EC5 T536 J UNV 1 
    $210.00 10%  3W EC  
    120  0.33  39.6  1.00  2850  72  2.53  0.91  >0.95  <20% 
    240  0.17  39.6  72  2.53  0.91  >0.95  <20% 
    277  0.14  38.8  73  2.58  0.93  >0.95  <20% 
    EcoSystem
    EC5 T539 J UNV 1 
    $210.00 10%  3W EC  
    120  0.37  44.0  1.00  2850  65  2.27  0.82  >0.95  <20% 
    240  0.18  44.0  65  2.27  0.82  >0.95  <20% 
    277  0.16  43.3  66  2.31  0.83  >0.95  <20% 
    Eco-10
    EC3 T536 G U 1 10 
    $150.00 5%  3W  
    120  0.33  39.6  1.00  2850  72  2.53  0.91  >0.95  <20% 
    240  0.17  39.6  72  2.53  0.91  >0.95  <20% 
    277  0.14  38.8  73  2.58  0.93  >0.95  <20% 
    EcoSystem
    EC5 T536 J UNV 2 
    $210.00 10%  3W EC  
    120  0.61  73.2  1.00  5700  78  1.37  0.98  >0.95  <20% 
    240  0.31  73.2  78  1.37  0.98  >0.95  <20% 
    277  0.26  72.0  79  1.39  1.00  >0.95  <20% 
    EcoSystem
    EC5 T539 J UNV 2 
    $210.00 10%  3W EC  
    120  0.70  84.3  1.00  5700  68  1.19  0.85  >0.95  <20% 
    240  0.35  84.0  68  1.19  0.86  >0.95  <20% 
    277  0.30  83.0  69  1.20  0.87  >0.95  <20% 
    Eco-10
    EC3 T536 G U 2 10 
    $150.00 5%  3W  
    120  0.61  73.2  1.00  5700  78  1.37  0.98  >0.95  <20% 
    240  0.31  73.2  78  1.37  0.98  >0.95  <20% 
    277  0.26  72.0  79  1.39  1.00  >0.95  <20% 
    40W EcoSystem
    EC5 T540 J UNV 1 
    $210.00 10%  3W EC  
    120  0.36  43.2  1.00  3100  72  2.31  0.93  >0.95  <20% 
    240  0.18  43.2  72  2.31  0.93  >0.95  <20% 
    277  0.16  44.3  70  2.26  0.90  >0.95  <20% 
    Eco-10
    EC3 T540 G U 1 10 
    $150.00 5%  3W  
    120  0.36  43.2  1.00  3100  72  2.31  0.93  >0.95  <20% 
    240  0.18  43.2  72  2.31  0.93  >0.95  <20% 
    277  0.16  44.3  70  2.26  0.90  >0.95  <20% 
    EcoSystem
    EC5 T540 J UNV 2 
    $210.00 10%  3W EC  
    120  0.64  76.8  1.00  6200  81  1.30  1.04  >0.95  <20% 
    240  0.32  76.8  81  1.30  1.04  >0.95  <20% 
    277  0.27  74.8  83  1.34  1.07  >0.95  <20% 
    Eco-10
    EC3 T540 G U 2 10 
    $150.00 5%  3W  
    120  0.64  76.8  1.00  6200  81  1.30  1.04  >0.95  <20% 
    240  0.32  76.8  81  1.30  1.04  >0.95  <20% 
    277  0.27  74.8  83  1.34  1.07  >0.95  <20% 
    EcoSystem
    EC5 T540 G UNV 3L 
    $210.00 10%  3W EC  
    120  0.95  113.2  1.00  8550  76  0.88  1.06  >0.95  <20% 
    240  0.47  112.4  76  0.89  1.07  >0.95  <20% 
    277  0.40  111.3  77  0.90  1.08  >0.95  <20% 
    Eco-10
    EC3 T540 G U 3 10 
    $150.00 5%  3W  
    120  0.95  113.2  1.00  9300  82  0.88  1.06  >0.95  <20% 
    240  0.47  112.4  83  0.89  1.07  >0.95  <20% 
    277  0.40  111.3  84  0.90  1.08  >0.95  <20% 
    50W EcoSystem
    EC5 T550 J UNV 1 
    $210.00 10%  3W EC  
    120  0.45  54.0  1.00  4000  74  1.85  0.93  >0.95  <20% 
    240  0.23  54.0  74  1.85  0.93  >0.95  <20% 
    277  0.20  55.4  72  1.81  0.90  >0.95  <20% 
    Eco-10
    EC3 T550 G U 1 10 
    $150.00 5%  3W  
    120  0.45  54.0  1.00  4000  74  1.85  0.93  >0.95  <20% 
    240  0.23  54.0  74  1.85  0.93  >0.95  <20% 
    277  0.20  55.4  72  1.81  0.90  >0.95  <20% 
    EcoSystem
    EC5 T550 J UNV 2 
    $210.00 10%  3W EC  
    120  0.84  100.8  1.00  8000  79  0.99  0.99  >0.95  <20% 
    240  0.42  100.8  79  0.99  0.99  >0.95  <20% 
    277  0.36  99.7  80  1.00  1.00  >0.95  <20% 
    Eco-10
    EC3 T550 G U 2 10 
    $150.00 5%  3W  
    120  0.84  100.8  1.00  8000  79  0.99  0.99  >0.95  <20% 
    240  0.42  100.8  79  0.99  0.99  >0.95  <20% 
    277  0.36  99.7  80  1.00  1.00  >0.95  <20% 
    55W EcoSystem
    EC5 T555 J UNV 1 
    $210.00 10%  3W EC  
    120  0.46  55.2  0.90  3888  70  1.63  0.90  >0.95  <20% 
    240  0.23  55.2  70  1.63  0.90  >0.95  <20% 
    277  0.20  55.4  70  1.62  0.89  >0.95  <20% 
    EcoSystem
    EC5 T555 J UNV 2 
    $210.00 10%  3W EC  
    120  0.92  110.4  0.90  7776  70  0.82  0.90  >0.95  <20% 
    240  0.46  110.4  70  0.82  0.90  >0.95  <20% 
    277  0.40  110.8  70  0.81  0.89  >0.95  <20% 

    Prices are subject to change without notice.

    * Actual lumen number may vary with lamp model. Please consult the lamp manufacturer for lamp-specific data.

    1-800-843-6036

    Email us

    OnLine Order

    Supported Browsers:  IE, SAFARI, CHROME

    MORE LUTRON PRODUCTS

    LUTRON ELECTRONIC DIMMING BALLAST BALLASTS          Web Prices

      Lutron invented the world's first electronic dimming ballast over 30 years ago.

    Dimming Ballast for T5-HO Linear Lamp

    Dimming Ballast for T5-HE Lamps

    Dimming Ballast for T5 Twin Tube Lamps

    Dimming Ballast for T8 Linear/U-bend Lamps

    Dimming Ballast for CFL Quad Tube Lamps Bulbs

    Dimming Ballast for CFL Triple Tube Lamp Bulb

     

     

    LUTRON Lighting Control Ballasts shipped quick from www.midsouthelectronics.com

     

    LUTRON Fluorescent Light Electronic Dimming Dimmer Ballasts Ballast for T5 Twin Tube Twin-Tube Lamp Lamps. Lamp Watts Wattage 55, 50, 40 & 36. 55w 50w 40w & 36w lamp wattage. Voltage 120, 240 & 277. 120v 240v & 277v voltage. Lutron Dimming Ballast model EcoSystem & Eco-10.

     

     

    Prices are subject to change without notice.  Inventory is subject to prior sale.  Product design, specifications & construction are subject to change without notice. Pictures are for general representational purposes and may not represent actual product.

    Not Responsible for errors in print, verify all data with us or manufacturer.  Terms & Conditions of sale apply, for a copy contact us. 

    Products may be discontinued without notice.  Pricing Does Not Include Freight Costs.  All trademarks remain property of their respective holders, and are used only to directly describe the products being provided. Other Disclaimers May Apply.